source: trunk/anuga_core/source/anuga/structures/test_culvert_routines_pipe_1pct.py @ 7982

Last change on this file since 7982 was 7939, checked in by steve, 14 years ago

Adding in culvert routines into structures directory

File size: 13.7 KB
Line 
1#!/usr/bin/env python
2
3
4import unittest
5import os.path
6import sys
7
8from anuga.utilities.system_tools import get_pathname_from_package
9from anuga.culvert_flows.culvert_routines import boyd_generalised_culvert_model
10import numpy as num
11
12
13class Test_culvert_routines_pipe_1pct(unittest.TestCase):
14    """
15        This unit test sets up 6 tests for various culvert conditions for a Circular Pipe Culvert on a 1.0% Slope
16    """
17
18    def setUp(self):
19        pass
20
21    def tearDown(self):
22        pass
23
24
25    def test_boyd_1(self):
26        """test_boyd_1
27       
28        This tests the Boyd routine with data obtained from ??? by Petar Milevski   
29        """
30        # FIXME(Ole): This test fails (20 Feb 2009)
31
32        g=9.81
33
34
35        inlet_depth=0.150
36        outlet_depth=0.15
37        inlet_velocity=1.00
38        outlet_velocity=0.5
39       
40        culvert_length=10.0
41        culvert_width=0.0
42        culvert_height=1.20
43       
44        culvert_type='circle'
45        manning=0.013
46        sum_loss=1.5
47
48        inlet_specific_energy=inlet_depth + 0.5*inlet_velocity**2/g
49        culvert_slope=1.0  # % Downward
50        z_in = 10.0
51        z_out = -culvert_length*culvert_slope/100
52        E_in = z_in+inlet_depth + 0.5*inlet_velocity**2/g
53        E_out = z_out+outlet_depth + 0.5*outlet_velocity**2/g
54        delta_total_energy = E_in-E_out
55        inlet_specific_energy=inlet_depth + 0.5*inlet_velocity**2/g
56
57        Q, v, d = boyd_generalised_culvert_model(inlet_depth,
58                                                 outlet_depth,
59                                                 inlet_velocity,
60                                                 outlet_velocity,
61                                                 inlet_specific_energy, 
62                                                 delta_total_energy, 
63                                                 g,
64                                                 culvert_length,
65                                                 culvert_width,
66                                                 culvert_height,
67                                                 culvert_type,
68                                                 manning,
69                                                 sum_loss)
70       
71        #print ('%s,%.2f,%.2f,%.2f' %('ANUGAcalcsTEST01 Q-v-d',Q,v,d))
72        #print('%s,%.2f,%.2f,%.2f' %('Spreadsheet_Boydcalcs', 0.113, 0.297, 0.443))
73        assert num.allclose(Q, 0.113, rtol=1.0e-1) #inflow
74        assert num.allclose(v, 0.297, rtol=1.0e-1) #outflow velocity
75        assert num.allclose(d, 0.443, rtol=1.0e-1) #depth at outlet used to calc v
76       
77    def test_boyd_2(self):
78        """test_boyd_2
79       
80        This tests the Boyd routine with data obtained from ??? by Petar Milevski   
81        """
82        # FIXME(Ole): This test fails (20 Feb 2009)
83
84        g=9.81
85        culvert_slope=1  # Downward
86
87        inlet_depth=0.500
88        outlet_depth=0.700
89        inlet_velocity=1.5
90        outlet_velocity=0.50
91       
92        culvert_length=10.0
93        culvert_width=0.0
94        culvert_height=1.20
95        culvert_width=0.0
96        culvert_type='circle'
97        manning=0.013
98        sum_loss=1.5
99
100        inlet_specific_energy=inlet_depth + 0.5*inlet_velocity**2/g
101        z_in = 0.0
102        z_out = -culvert_length*culvert_slope/100
103        E_in = z_in+inlet_depth + 0.5*inlet_velocity**2/g
104        E_out = z_out+outlet_depth + 0.5*outlet_velocity**2/g
105        delta_total_energy = E_in-E_out
106
107        Q, v, d = boyd_generalised_culvert_model(inlet_depth,
108                                                 outlet_depth,
109                                                 inlet_velocity,
110                                                 outlet_velocity,
111                                                 inlet_specific_energy, 
112                                                 delta_total_energy, 
113                                                 g,
114                                                 culvert_length,
115                                                 culvert_width,
116                                                 culvert_height,
117                                                 culvert_type,
118                                                 manning,
119                                                 sum_loss)
120       
121        #print ('%s,%.3f,%.3f,%.3f' %('ANUGAcalcsTEST02 Q-v-d',Q,v,d))
122        #print ('%s,%.3f,%.3f,%.3f' %('Spreadsheet_Boydcalcs', 0.108, 0.152, 0.721))
123        assert num.allclose(Q, 0.108, rtol=1.0e-1) #inflow
124        assert num.allclose(v, 0.152, rtol=1.0e-1) #outflow velocity
125        assert num.allclose(d, 0.721, rtol=1.0e-1) #depth at outlet used to calc v 
126
127    def test_boyd_3(self):
128        """test_boyd_3
129       
130        This tests the Boyd routine with data obtained from ??? by Petar Milevski   
131        """
132        # FIXME(Ole): This test fails (20 Feb 2009)
133
134        g=9.81
135        culvert_slope=1  # Downward
136
137        inlet_depth=1.800
138        outlet_depth=0.80
139        inlet_velocity=1.0
140        outlet_velocity=0.5
141       
142        culvert_length=10.0
143       
144        culvert_height=1.20
145        culvert_width=0.0
146        culvert_type='circle'
147        manning=0.013
148        sum_loss=1.5
149
150        inlet_specific_energy=inlet_depth + 0.5*inlet_velocity**2/g
151        z_in = 0.0
152        z_out = -culvert_length*culvert_slope/100
153        E_in = z_in+inlet_depth + 0.5*inlet_velocity**2/g
154        E_out = z_out+outlet_depth + 0.5*outlet_velocity**2/g
155        delta_total_energy = E_in-E_out
156
157        Q, v, d = boyd_generalised_culvert_model(inlet_depth,
158                                                 outlet_depth,
159                                                 inlet_velocity,
160                                                 outlet_velocity,
161                                                 inlet_specific_energy, 
162                                                 delta_total_energy, 
163                                                 g,
164                                                 culvert_length,
165                                                 culvert_width,
166                                                 culvert_height,
167                                                 culvert_type,
168                                                 manning,
169                                                 sum_loss)
170        #print ('%s,%.2f'%('SPEC_E = ',inlet_specific_energy))
171        #print ('%s,%.2f'%('Delta E = ',delta_total_energy))
172        #print ('%s,%.2f,%.2f,%.2f' %('ANUGAcalcsTEST03 Q-v-d',Q,v,d))
173        #print ('%s,%.2f,%.2f,%.2f' %('Spreadsheet_Boydcalcs', 3.441, 3.042, 1.2))
174        assert num.allclose(Q, 3.441, rtol=1.0e-2) #inflow
175        assert num.allclose(v, 3.042, rtol=1.0e-2) #outflow velocity
176        assert num.allclose(d, 1.2, rtol=1.0e-2) #depth at outlet used to calc v
177
178#NOTE FROM HERE DOWN THE UNITS TEST HAVE NOT BEEN AMENDED TO ALLOW VELOCITY COMPONENT TO BE USED. ONLY ABOVE 3 TESTS WORK. PM WILL FIX THE ONES BELOW WHEN THE ABOVE 3 ARE WORKING
179    def test_boyd_4(self):
180        """test_boyd_4
181       
182        This tests the Boyd routine with data obtained from ??? by Petar Milevski   
183        """
184        # FIXME(Ole): This test fails (20 Feb 2009)
185
186        g=9.81
187        culvert_slope=1  # Downward
188
189        inlet_depth=1.00
190        outlet_depth=0.9
191        inlet_velocity=1.0
192        outlet_velocity=0.5 
193        culvert_length=10.0
194        culvert_width=0.0
195        culvert_height=1.20
196       
197        culvert_type='circle'
198        manning=0.013
199        sum_loss=1.5
200
201        inlet_specific_energy=inlet_depth + 0.5*inlet_velocity**2/g
202        z_in = 10.0
203        z_out = 10.0-culvert_length*culvert_slope/100
204        E_in = z_in+inlet_depth + 0.5*inlet_velocity**2/g
205        E_out = z_out+outlet_depth + 0.5*outlet_velocity**2/g
206        delta_total_energy = E_in-E_out
207
208
209
210        Q, v, d = boyd_generalised_culvert_model(inlet_depth,
211                                                 outlet_depth,
212                                                 inlet_velocity,
213                                                 outlet_velocity,
214                                                 inlet_specific_energy, 
215                                                 delta_total_energy, 
216                                                 g,
217                                                 culvert_length,
218                                                 culvert_width,
219                                                 culvert_height,
220                                                 culvert_type,
221                                                 manning,
222                                                 sum_loss)       
223        #print ('%s,%.2f'%('SPEC_E = ',inlet_specific_energy))
224        #print ('%s,%.2f'%('Delta E = ',delta_total_energy))
225        #print ('%s,%.2f,%.2f,%.2f' %('ANUGAcalcsTEST04 Q-v-d',Q,v,d))
226        #print ('%s,%.2f,%.2f,%.2f' %('Spreadsheet_Boydcalcs', 1.559, 1.694, 0.91))
227        assert num.allclose(Q, 1.559, rtol=1.0e-2) #inflow
228        assert num.allclose(v, 1.694, rtol=1.0e-2) #outflow velocity
229        assert num.allclose(d, 0.91, rtol=1.0e-2) #depth at outlet used to calc v
230
231    def test_boyd_5(self):
232        """test_boyd_5
233       
234        This tests the Boyd routine with data obtained from ??? by Petar Milevski   
235        """
236        # FIXME(Ole): This test fails (20 Feb 2009)
237
238        g=9.81
239        culvert_slope=1  # Downward
240
241        inlet_depth=1.50
242        inlet_velocity= 1.0
243        outlet_depth=1.3
244        outlet_velocity=0.5
245        culvert_length=10.0
246        culvert_width=0.0
247        culvert_height=1.20
248       
249        culvert_type='circle'
250        manning=0.013
251        sum_loss=1.5
252
253        inlet_specific_energy=inlet_depth + 0.5*inlet_velocity**2/g
254        z_in = 10.0
255        z_out = 10.0-culvert_length*culvert_slope/100
256        E_in = z_in+inlet_depth + 0.5*inlet_velocity**2/g
257        E_out = z_out+outlet_depth + 0.5*outlet_velocity**2/g
258        delta_total_energy = E_in-E_out
259
260
261
262        Q, v, d = boyd_generalised_culvert_model(inlet_depth,
263                                                 outlet_depth,
264                                                 inlet_velocity,
265                                                 outlet_velocity,
266                                                 inlet_specific_energy, 
267                                                 delta_total_energy, 
268                                                 g,
269                                                 culvert_length,
270                                                 culvert_width,
271                                                 culvert_height,
272                                                 culvert_type,
273                                                 manning,
274                                                 sum_loss)       
275        #print ('%s,%.3f'%('SPEC_E = ',inlet_specific_energy))
276        #print ('%s,%.3f'%('Delta E = ',delta_total_energy))
277       
278        #print ('%s,%.3f,%.3f,%.3f' %('ANUGAcalcsTEST05 Q-v-d',Q,v,d))
279        #print ('%s,%.3f,%.3f,%.3f' %('Spreadsheet_Boydcalcs',2.258, 1.996, 1.20))
280        assert num.allclose(Q, 2.258, rtol=1.0e-2) #inflow
281        assert num.allclose(v, 1.996, rtol=1.0e-2) #outflow velocity
282        assert num.allclose(d, 1.20, rtol=1.0e-2) #depth at outlet used to calc v
283
284    def test_boyd_6(self):
285        """test_boyd_6
286       
287        This tests the Boyd routine with data obtained from ??? by Petar Milevski   
288        """
289        # FIXME(Ole): This test fails (20 Feb 2009)
290
291        g=9.81
292        culvert_slope=1  # Downward
293
294        inlet_depth=1.50
295        inlet_velocity= 4.0
296        outlet_depth=0.80
297        outlet_velocity=4.0
298        culvert_length=10.0
299        culvert_height=1.20
300        culvert_width=0.0
301        culvert_type='circle'
302        manning=0.013
303        sum_loss=1.5
304
305        inlet_specific_energy=inlet_depth + 0.5*inlet_velocity**2/g
306        z_in = 10.0
307        z_out = 10.0-culvert_length*culvert_slope/100
308        E_in = z_in+inlet_depth + 0.5*inlet_velocity**2/g
309        E_out = z_out+outlet_depth + 0.5*outlet_velocity**2/g
310        delta_total_energy = E_in-E_out
311
312
313
314        Q, v, d = boyd_generalised_culvert_model(inlet_depth,
315                                                 outlet_depth,
316                                                 inlet_velocity,
317                                                 outlet_velocity,
318                                                 inlet_specific_energy, 
319                                                 delta_total_energy, 
320                                                 g,
321                                                 culvert_length,
322                                                 culvert_width,
323                                                 culvert_height,
324                                                 culvert_type,
325                                                 manning,
326                                                 sum_loss)       
327        #print ('%s,%.3f,%.3f,%.3f' %('ANUGAcalcsTEST06 Q-v-d',Q,v,d))
328        #print ('%s,%.3f,%.3f,%.3f' %('Spreadsheet_Boydcalcs',3.472, 3.070, 1.20))
329        assert num.allclose(Q, 3.472, rtol=1.0e-2) #inflow
330        assert num.allclose(v, 3.070, rtol=1.0e-2) #outflow velocity
331        assert num.allclose(d, 1.20, rtol=1.0e-2) #depth at outlet used to calc v
332# =========================================================================
333# =========================================================================
334
335if __name__ == "__main__":
336    suite = unittest.makeSuite(Test_culvert_routines_pipe_1pct, 'test')
337    runner = unittest.TextTestRunner()
338    runner.run(suite)