Changeset 8798


Ignore:
Timestamp:
Apr 1, 2013, 9:48:50 PM (12 years ago)
Author:
mungkasi
Message:

Modifying automated report for subcritical flow.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/anuga_core/source/anuga_validation_tests/Analytical_exact/subcritical_over_bump/results.tex

    r8797 r8798  
    11
    2 \section{Subcritical flow over a bump without a shock}
     2\section{Subcritical flow without a shock over a bump}
    33
    44This is a subcritical flow over a bump. This test is adapted from Goutal and Maurel~\cite{GM1997}. No shock occurs in this scenario.
     
    2727w(x,y,0)= 0.2\,,
    2828\end{equation}
    29 and the Dirichlet boundary conditions at $x=0^{-}$ and $25^{+}$ to be $[w,hu,hv]=[2, 4.42, 0]$\,.
     29and the Dirichlet boundary conditions at $x=0^{-}$ and $25^{+}$ to be
     30\begin{equation}
     31[w,hu,hv]=[2, 4.42, 0]\,.
     32\end{equation}
    3033Representatives of the simulation results are given in the following three figures. Even though we have small discrepancy in the numerical and analytical momenta, these numerical an analytical solutions should agree quite well.
    3134
Note: See TracChangeset for help on using the changeset viewer.